How to install and how to check compatibility with your existing access control solution?

For the Bold Controller to operate it requires a common open/close interface on your existing electronic access control solution. You need to connect this interface to the 2-wire switching interface on the bottom of the Bold Connect. 

This (potential free relay) switch interface is programmable using the Bold App. 

Currently different settings are under development which will include: 

  • Normal Open (NO) vs Normal Closed(NC), 
  • ShortPush or Configurable Activation Time 
  • Permanent ON/OFF Switching mode. 

The maximum electronic load is max. 3A at max. 250VAC. 

Please compare this information with the specifications of your electronic access control solution to confirm compatibility and the right push button switch wiring configuration.